Usura che resiste al fan centrifugo indotto del ventilatore del fan di progetto 15000 M3h
Applications♦ VentilatingForced ventilating, Building ventilating, Mine ventilating, Tunnel ventilating, Materials ventilating and drying.♦ Industrial boiler blowing air, Industrial boiler inducing air, Industrial boiler waste gas dust collecting.♦ Industrial boiler blowing air, Industrial boiler inducing air, Industrial boiler primary air, Industrial boiler secondary air.♦ Brick kiln blowing air, Brick kiln inducing air. Performance ApplicationTemperatureNormal temperature
Ventilatore azionato a cinghia del forno 75kw di alta efficienza per la progettazione dell'aria delle caldaie a vapore
Applications for belt driven kiln fan 75 kw ♦ Industrial boiler blowing air, Industrial boiler inducing air, Industrial boiler waste gas dust collecting. Performance Application Temperature Normal temperature Air Hot Air Air composition Clean air Dusty air Corrosive gas Combustible gas Powder materials Light particle materials Performance Impeller diameter 800~2950 mm Speed of mainshaft 730~1450 rpm Pressure range 553~7218 Pa Flow range 5229~48000 m3/h Structure Blade
HG785 il raffreddamento di lunga vita del fan di identificazione di acciaio legato Antifraying
HG785 Alloyed Steel Antifraying Long Life Cooling Induced Draft Fan Introduction Of Centrifugal Fan Medium requirements for 6-08 series fans: The medium to be transported should be non-corrosive, non-flammable, explosive, and free of viscous substances. The dust and hard particles contained in the medium should be no more than 150mg/m3. Medium temperature: The medium temperature of standard fans is not more than 80 °C, the V-belt driving type fan can transport media below 150
materiali medi di anticorrosivo di pressione 16Mn che asciugano il fan di progetto indotto
16Mn Medium Pressure Anticorrosion Materials Drying Induced Draft Fan Introduction Of Centrifugal Fan Medium requirements for 6-08 series id fan in boiler: The medium to be transported should be non-corrosive, non-flammable, explosive, and free of viscous substances. The dust and hard particles contained in the medium should be no more than 150mg/m3. This series of fans is a new type of high efficiency industrial fan in the field of small flow and medium pressure. Technical
Fan di progetto indotto di andata lega alluminio di metallurgia della singola entrata
Aluminium Alloyed Single Inlet Forward Metallurgy Induced Draft Fan Introduction Of Centrifugal Fan 6-06 series draftfan is generally used for gas transportation of granular or powdery materials, and can be widely used to transport air and non-corrosive non-self-igniting, non-viscous substances. The fan speed can be flexibly set by matching different belt pulley diameters to make the fan run at the highest efficiency point and reduce energy waste. Technical data series model
Fan di progetto indotto in grande quantità della fonderia di esplosione di acciaio al carbonio anti
Carbon Steel High Volume Anti-Explosion Foundry Induced Draft Fan Introduction Of Centrifugal Fan This series of induced draft is a new type of high efficiency industrial fan in the field of small flow and medium pressure. According to customer performance requirements customized design, and optimized by CFD technology, the energy consumption is lower than similar models. The fan speed can be flexibly set by matching different belt pulley diameters to make the fan run at the
Fan di progetto indotto ad alta resistenza dell'acciaio con la curva di prestazione piana
Q345 High Strength Steel Induced Draft Industrial Blower Fan Introduction The 6-11 series have the characteristics of high efficiency, flat performance curve, wear resistance, and work stability. It has excellent performance and can output high pressure. Q345 High Strength Steel Induced Draft Industrial Blower Fan can be used to transport normal temperature or high temperature non-flammable gases, particles, powder, debris, fibrous materials etc. The fans are commonly used in
Doppia caldaia del fan di progetto indotto di ventilazione 3187pa dell'entrata
Double Inlet Efficient Energy-Saving Ventilation Induced Draft Fan Introduction: The 4-09 series large-flow centrifugal fan is the earliest used fan in China, and it is also the most commonly used fan. Suitable for conveying clean air or light materials at normal temperature, most commonly used in industrial furnaces for air supply, light particle/powder/crush/fiber transportation, air drying/cooling of materials, ventilation and smoke exhaust, and other areas. No viscous
Coppia determinando l'iniezione del carbone di acciaio inossidabile del fan di induzione del progetto
Coupling Driving Stainless Steel Coal Injection Induced Draft Fan Introduction Of Centrifugal Fan The 5-06 series fan can be used in the feeding system of 2-670t/h steam boiler in thermal power plants, it can also meet the requirements of the high-pressure head performance parameters of the fluidized bed furnace. This series of fans can also be used for dust removal, mine ventilation and general ventilation systems. The blower delivers air, and the induced draft fan delivers
Forni industriali di andata lega alluminio del fan di progetto indotto
Aluminium Alloyed Forward Industrial Kilns Induced Draft Fan Introduction Of Centrifugal Fan 6-04 series fans have high pressure coefficient, low peripheral speed, low noise, flat performance curve and wide area of high efficiency. Bearing cooling method: according to gas temperature and operating environment conditions choose low-cost water-cooling method or oil-cooling method with good heat dissipation performance. For extremely high temperature operating conditions, can
V resistenza all'usura ad alta temperatura azionata a cinghia del fan di progetto indotto alta
V-Belt Driven High Temperature High Wear Resistance Induced Draft Fan Introduction Of Centrifugal Fan 1. The variable inlet damper can be used to flexibly adjust the pressure and flow of the fan during operation. The variable frequency motor can also be selected to adjust the pressure and flow of the fan by changing the speed. 2. The fan is equipped with temperature and vibration sensors, which can easily install the fan operation monitoring device. 3. Made of high quality
Coppia guidando l'anti fan di progetto indotto industriale di esplosione
Coupling Driving Industrial Anti-Explosion Induced Draft Fan Introduction Of Centrifugal Fan 6-06 series centrifugal fan is generally used for gas transportation of granular or powdery materials, and can be widely used to transport air and non-corrosive non-self-igniting, non-viscous substances. The temperature of the medium generally does not exceed 50°C (max 80°C), the dust and hard particles contained in the medium is not more than 150 mg / m3. It is suitable for
Resistenza all'usura media del fan di progetto indotto di pressione di acciaio inossidabile alta
Stainless Steel Medium Pressure High Wear Resistance Induced Draft Fan Introduction Of Centrifugal Fan 6-06 series centrifugal fan is generally used for gas transportation of granular or powdery materials, and can be widely used to transport air and non-corrosive non-self-igniting, non-viscous substances. The fan has high efficiency, high total pressure, low noise, flat performance curve, wide economical use area, and adopts backward plate type blades. The efficiency of the
Fan di progetto indotto a rovescio economizzatore d'energia efficiente di grande capacità
Large Capacity Efficient Energy-Saving Backward Induced Draft Fan Introduction Of Centrifugal Fan 6-06 series centrifugal fan is generally used for gas transportation of granular or powdery materials, and can be widely used to transport air and non-corrosive non-self-igniting, non-viscous substances. For the material of impeller and main shaft, we will choose high-strength carbon steel, low-alloy steel, high-temperature alloy steel, high temperature resistant high-strength
Anticorrosivo medio del fan di progetto indotto di pressione del motore a corrente alternata
AC Motor Medium Pressure Anticorrosion Induced Draft Centrifugal Fan Introduction Of Centrifugal Fan Medium requirements for 6-08 series fans: The medium to be transported should be non-corrosive, non-flammable, explosive, and free of viscous substances. The dust and hard particles contained in the medium should be no more than 150mg/m3. Medium temperature: The medium temperature of standard fans is not more than 80 °C, the V-belt driving type fan can transport media below
Azionamento resistente della cinghia del ventilatore centrifugo di progetto indotto di pressione bassa V
Heavy Duty Low Pressure V-Belt Driving Induced Draft Centrifugal Fan Introduction Of Centrifugal Fan The 4-09 series large-flow centrifugal fan is the earliest used fan in China, and it is also the most commonly used fan. No viscous substances are allowed inside the gas, and the dust and hard particles contained in the gas are larger than 150 mg/m3, and the gas temperature does not exceed 80°C. In addition to the industrial system, it is also frequently used in agriculture
Fan di progetto indotto di andata di anticorrosivo di rendimento energetico dell'acciaio legato di pressione bassa
Low Pressure Alloy Steel Energy Efficiency Forward Anticorrosion Induced Draft Fan Introduction Of Centrifugal Fan The 4-09 series large-flow centrifugal fan is the earliest used fan in China, and it is also the most commonly used fan. No viscous substances are allowed inside the gas, and the dust and hard particles contained in the gas are larger than 150 mg/m3, and the gas temperature does not exceed 80°C. Technical data series model Rotation Speed (r/min) Total Pressure
Fan di progetto indotto resistente alla corrosione della caldaia a vapore di grande capacità Q235
Q235 Large Capacity Corrosion Resistant Steam Boiler Induced Draft Fan Introduction Of Centrifugal Fan G4-10 and Y4-10 series ventilation and induced draft fans are suitable for the ventilation and induced draft fan systems of 2~670T/h steam boilers in thermal power plants. Technical data series model Rotation Speed (r/min) Total Pressure (Pa) Air Capacity (m³/h) Power (kW) 4-10 8D 1450 2104~1400 16156~30993 18.55 9D 960 ~ 1450 775 ~ 2668 15229 ~ 44128 11 ~ 37 10D 730 ~ 1450